Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

gc Calibration % RSD failed what is the possible reasons?

Answer Posted / ahmed

Also because of glass liner damages

Is This Answer Correct ?    8 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

is it nessesary to do solution stability for 7 days?

762


why we are using benzene, anyline in acetic anhdride assay titration method?

2106


if tech transfer fails whay require to do?

830


2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.

2212


what is turbidimetric titration?Give 2 examples.

2649


A ha tc is actual defination of retention time?

1612


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1964


how to qualify the impurity?

856


How to calibration of the uv spectroscopy and its test?

1188


how to develop the icp ms method? Application of icp ms?

800


What is the main difference between ODS1 and ODS2 Hplc column.

5198


we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

1861


all types of questions asked at the cipla interview

4674


what you do when compound having dwel wavelength?

737


why should we perform dissolution PVT calibration only by UV spectrometer, not by HPLC ?

1701