Answer Posted / narendra mishra
Infrared or ultraviolet(IR/UV) energy is emitted from a heated filament in a chamber.when gas is passed through it,a detector measures IR/UV wavelength absorption by the gas which is the property of that gas.this is compared to the reference condition i.e at no absorption.radiation spectrum is limeited to absorption band of gas.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Explain bernoulli’s theorem.
Draw block digram for well head from well to shipping pump?
Hi, I am Newely Joined in Construction company instrument engineer? Any one can Plz tell me How can I advanced preparation for Releated Engineering and construction Documents?
What is standard procedure of manual mapping in Radar type level transmitter?
Why we are using DPT(Differential Pressure Transmitter) in separator instead of level trasmitter?
what is the difference between Cv and air consumption? why the customer needs Air consumption details?
Which types of quections asked in interview for FORMULATION PLANT (PHARMA)
A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?
In a gas over oil actuator, after the opening/closing of valve, how the gas is vented out? How does the hydraulic/gas circuit function?
what is the input to be given in digital flow meter during the the calibration time?
WHY THE DEGREE OF VALVE PLUG AND VALVE SEAT IS SLIGTLY DIFFERENT I CONTROL VALVE TRIM DESIGN
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
How does your previous experience relate to the job you are applying for ?
any body who gone thru recent iocl interview.INSTRUMENTATION questions. I need.
WHAT ARE THE INSTRUMENTAL DIAGRAMSOF VALVES?