What is use of condensate pot

Answer Posted / shad ahmad

The main purpose of condensate pot is to catch and hold condensate and foreign material. This prevents damage to the metering system and/or manifold. The condensate may be drained from the bottom valve connection. OS&Y gate or ball valves to be used as the drain port.

Condensate chambers are used as a barrier between the main line and the secondary instruments in the measurement of steam or other vapors which condense to a liquid state insuring compatibility with the secondary instruments. They can also be used to cool down very high temperature liquids. Seal pots are installed where the line fluid is corrosive or viscous to the extent where it cannot be permitted to contact the secondary instrument. (transmitter or gauge) thereby acting as a liquid barrier between the line fluid and the condensate.

Is This Answer Correct ?    13 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the procedure to callibrate temp controller ,pressure controller,etc. suppose a temp controller showing error 1.5 degree centigrate how can i minimize it.

1877


Draw a complete P&ID of a flow suction tank indicating all control & protection equipment. Indicate all its inlets and outlets. Explain the controls for this system

1108


Whether the DI, DOs shields can be connected with Analog Input Shield Earthpit?

1433


where proximity sensor installed on tank in loading arm application

1795


List three types Level Switches with their working principles

1629






how to calculate signal cable sizing? and multipair cable sizing??explain in brief?

1906


A valve in series with an orifice plate (DP transmitter), is aligned for constant pressure in the pipeline, if there is an error dx, How to align it in process.

877


There are many type of control cable like pair,core,tried, What are defination each one

1742


If fire would be inside the plant which fire detector is to detected the fire.

1080


Which products are available in the Mass Systemswitch and System Manager AC range?

1499


What is heating effect?

1886


we have level transmitter for h2s04 storage tank capacity 10k ,always there are failure of transmitter due to failure of magnetic floats ,please come up with solutions at the earliest.

1603


IN CONTROL VALVE SPECIFICATIONS GENERALLY TERM " DE- 200" ."DM -400"USED,, WHAT IS DE/ DM STANDS FOR?

1768


Why is the orifice tab provided?

715


which type of signal used in instrument?

8617