Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why a vaccum is created in condenser

Answer Posted / sethu

How vacuum is created?

Basic vacuum created in the LPT exhaust side is because of condensing process. Phase change is occurring at the exhaust side i.e. conversion of steam into water. Specific volume of water is much lower than the steam.Hence when the condensing process happens, volume of steam reduces and basic vacuum is created.

Apart from this, vacuum pumps are provided to remove non condensable gases/air ingress which reduces heat transfer effectiveness.

Why vacuum is created?
To improve LPT cylinder efficiency & thus the load/work done shall be improved.

Effect of over vacuum?
It causes sub-cooling effect where hot well temperature reduces more than design which required to be added in boiler leads to heat loss. Also flow accelerated erosion in LPT last stages.

Effect of under vacuum?
LPT efficiency reduction which causes lesser work done & leads to reduced load output.

Is This Answer Correct ?    59 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is transient Phenomenon?

2243


What is the ratio of Booster transformer?

2159


how does high earth to neutral voltage affects electronic circuit?

1950


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2146


how to check avr of dg set of 125kva

2591


volts=230 c=10mf a=??

2028


Why are iron cores in transformers made laminated?

1111


hi, i finished b.tech eee in 2008, im worked in dg sets mfg company , now i left job in 6months back, now again i want get job core side, how can i get? is there any couses we have learn to get better oppurtunity? /

1958


which fault is severe and why?between lll fault and lllg fault which fault is severe and y?

2497


what is DRP panels?

2132


what is cause of static electricity? I experience shock when i touch metal equipment in a room ,furher check shows earth leakage showing 80ma at the DB near to the 400 MCCB?

1897


Define what is the function of anti-pumping in circuit breaker?

1311


why the frequency and voltage in india is 230v and 50HZ. when compared to USA say 110v and 60 HZ.

1439


please suggest some good universities with low cost iam in totally full confusion so please help me my profile gre 283 and ielts 5.5

1594


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?

1918