Question - Chemical Engineering Material - In crystal material, hexagonal crystal system could form 4-digit index in certain direction of solid. For [1(-1)0] direction in the hexagonal crystal systems of particular catalyst applied in fume removal of incinerator, what is the four-digit index for this direction? Hint : The transformation equations between the 3-digit [h’k’l’] and the 4-digit [hkil] indices are : h = (1/3) (2h’ – k’); i = - (h + k); k = (1/3) (2k’ – h’); l = l’. A. [(-1)100] B. [1(-1)00] C. [(-1)000] D. [00(-1)(-1)] E. [(-1)0(-1)0]
Answer Posted / kang chuen tat
Answer : h = (1/3) [ 2 - (-1) ] = 1; k = (1/3) ( - 2 - 1 ) = -1; i = - ( 1 - 1 ) = 0; l = i = 0. Solution is [1(-1)00]. Answer is B. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
sir, kindly explain to me that how to calculate volume of torrispherical vessel which is used in pharma company ss reactor bottom dish volume. thank u.
How can one determine the particle size distribution for a given bulk solid?
how can we calculate reflux ratio? what is difference between internal reflux and external reflux?
Can any one send me the sample test papers of IOCL entry exam to be held on 6th july 2008. Also plz send the interview questions that cud probably be asked........i wud be highly obliged if u can send a few test paers and other stuff @ inderjeetd@gmail.com.........Inderpreet
could anyone send me model question papers or outline of graduate trainee(chemical engg) post?
How to size the cooling tower sump / basin for any given circulation rate? What is the guideline?
Is there any way to repair a valve that is passing leaking internally without taking our process offline?
What is difference between Piping Standard & Piping Specification ?
How do you design a vapor-liquid separator or a flash drum?
We are having proplem with the persperation smell in ETT/ECHO room in our cardiac hospital.The 2 Ton of AC is not conditioning the environment. We have to use exhaust fan to through out of the room bad air. Could anyone suggest how to coup with this effectively using chemical engineering. Any permanent solution to neutralise the bad smell.The Air freshners are not doing enough instead making a bad odour.
What is the procedure to estimate the friction factor involved in heat exchanger tubes?
What factors go into designing the vapor space of kettle type reboiler?
What is the most common carrier gas used in pneumatic conveying?
What does the catalytic converter on an automobile do?
Dear sir/madam I am in final year BE chemical engineering.Which companies i can apply .Please guide me.It is very helpful for me