Answer Posted / saida shaik
KVA is the unit for apparent power
Apparent power consists of Active and Reactive power. Active power is transmits energy from the source to the user. Reactive power is represents a usless oscillation of energy from the source to the user and back again. Reactive power occurs when on account of some inertia in the system there is a phase shift between voltage and current. This means that the current dose not change polarity synchronous with the volage but the heat generated in a winding as well as the eddy current losses generated in a t/f core depend on the current only ,regardless of whether it aligns with the voltage or not. Therefore the heat is always propotional to the square of the current amplitude irrespective ofphase angle so a t/f has to be rated by apparent power.(it means KVA instead of KW)
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
why most of junction box vendors providing T5/T6 Temp class jb's for T3 area any special reason?
for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance
How many capacitors using in LT panel as per Govt rules?
how to interlock 3 incomer-ACB,1 buscoupler ACB,... pls answer this question and if possible send me the ckt diagram..haifriends2910@gmail.com
What are factors to be considered while we selecting the Core Balance Current Transformer for Earth fault protection
What is Auto Mains Failure Panel & Auto Synchronizing Panel
what is the difference between torque induced and torque load?compare them with respect to dc motor?
How to calculate capacitor bank value to maintain unity power factor with some suitable example?
what is the use of expulsition protective gap in 11Kv line.
What is the normal phase difference between the voltage and the no-load current in a transformer?
what r the safety measures in UPS ? explain all?
Why strting torqe high in inducation motor?
How to calculate earth fault current for 6.6 KV , 50 HZ , 756 Amps , 3000 RPM , 0.8 PF generator
Dear sir my name Ankit i m Diploma holder present working in Welspun Corp ltd Anjar as Asst.engg (salary 14400/month ctc) i Would like to change my company also i have selected in ford India pvt ltd Sanand as trainee Tech with salary 12000/month so please suggest me for changing my job hope for *ve response
how to caculate cable size for diff types of loads? if anyone know the calculating procedure please tell me