what is commissioning & pre commissioning , explain with
difination
Answer Posted / kalpesh g patel
Commissioning is the start up of the equipment for the first time. It is when you run the equipment and carry out tests to verify it is running as intended i.e. to design specifications. Commissioning tests are normally run against a design data baseline. Commissioning also includes things like checking oil levels, fluid levels, temperatures, pressures and for general issues that are contradictory to the intended correct operation of the equipment.
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
1. For Steam drum level signal, why do we compensate with drum pressure signal? 2.For main steam Flow signal is comensated with main steam temperature signal and main steam pressure signal why?
Explain the difference between mmwc and mmwg?
why we use 3 wire rtd direct wiring for temperature measurement instead of temperature transmitter like bearing temperature
Hi,can anyone help me out with PhD programs related to Instrumentation field?I have a degree in electronic Instrumentation?
Tell me the field calibration procedure step by step with diagram of pressure gauge, pressure switch, pressure transmitter, temperature switch, level switch, flow switch, flow transmitter.
Sir, I want junior executive, Instrumentation question papaer for IOCL, Plz send to arabinda.ghosh83@gmail.com
what is intrinscily safe system and where we use?
What is Droop? What is Step/Gradient Limiter in Turbine Governor control?
What is the purpose of the analyzer in petrochemical plant?
what is gas metering system? gas chromatograph? and gas compressors?
please someone tell me what is function of vibration sencer and how many types and how to control viberation.please. my id is jimmykhan077@gmail.com
We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.
Name different parts of a pressure gauge.
what would be the minimum flow rate that we can measure on rotameter..?
Meaning of the following a. IOP- Manimum; b. IOP- Maximu,;