why the impedence of the transformer is expressed in percentage?
Answer Posted / afsal
Percentage impedance is the ratio of voltage drop on full load due to winding resistance and leakage reactance to the rated voltage of the transformer.
Z%= Vd/Vr *100
this can varied at the design stage by varying voltage per turns and geometrical size of the windings.
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
how to build a network which step down 415v to 1v rms
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
with help of neat sketch explain principle of TIG welding process
Mention the disadvantages of low power factor? How can it be improved?
What is the working mechanism of OLTC in Power Transformers????
What is the difference between DOL starter and star delta starter
Is there any reason that we get shock on touching phase wire because the earth is at neutral potential? Is there any reason that the earth is at neutral potential because the neutral is earthed in apower station
Meter p.t. ratio= 3×230/400 , c.t.ratio = 3×1 (2) A what is m.f.
hr round
what is the current setting for different relay protection for transformer .
specific difference of ICT&Auto Transformer
WHAT IS THE TOTAL POWER GENERATION IN CHHATTISGARH?
what is sevice settings for mccb?How can be it setted?
Why frame of the motor is specified?. If we mention KW and voltage level,automatically frame is decided or separately frame is compulsory to mention?.
In single phase capacitor motor, if the motor rotate reverse direction then how much power will be consumed by the motor and why?