Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the ka rating of mccb.
and how it is decided .

Answer Posted / saraz06a0222

The value of the kA rating determines how much current the circuit breaker can withstand under fault conditions. The circuit breaker only has to withstand this for a brief period of time, usually the time it takes for the circuit breaker to trip. For example, a value of 6kA means that the circuit breaker can withstand 6,000 amps of current during the brief time it takes to trip.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is pi controller?

1177


how to calculate the no load current in transformer?

2517


A logic circuit that provides a HIGH output if one input or the other input, but not both, is HIGH, is a(n)?

1223


what is the difference between vector scale and vector diagram?

4448


how we can calculate 2 phase welding transformer rating or total power?

1857


model question paper for supervisor trainee

2032


Why does amplifier gain reduce?

1051


How one may guess the direction from which the distribution line is incoming if there is no pole plate on poles?

2173


Why colled 440V to 3-phase supply.

2142


what is the difference between dry and wet type of 132kV terminations. which one is durable

1995


we have 3.5MVA-11/6KV transformer. how can we calculate earth fault current and NGR calculation?

1527


How generator NPS(NEGATIVE PHASE SEQUENCE TEST)TEST WAS DONE? PROCEDURE WITH DETAILS?

2216


What is the lockout relay

1530


I have one ct of ratio 3000-2000/1 Amp its knee point voltage mentioned on name plate is 500-333/30mA-50mA at Vk/2. in secondary box there is three terminal named 1S1, 1S2, 1S3 then on which terminal obtained the knee point voltage ie 1S1-1S2 OR 1S1-1S3 & also specify the knee point voltage for the ratio 3000 from name plate.

2438


how to protect motor in dol starter having capacity of 30 hp.40 hp?

3205