Is it possible to run HT motor through LT VFD (LT VFD supply given to Transformer LT side and transformer HT side connected to motor)
Answer Posted / kingshuk dey
To start with, let's get our concepts correct. The motor supply comes from the VFD, which in turn is connected to the power supply from a board (or LT side of transformer, in your case).
Supply(TRF) --> VFD --> Motor
First off lets assume your VFD type is less than or equal to this LT supply. (LT/HT for TRF is subjective, Lt can be 220V when HT is 460V, or 460V when HT is 1000V etc). But a 460V VFD will burn its fuses if connected to 1000V.
Anyway, if you connect the VFD to LT side, and the motor is HT (meaning it's rated for a heavy current like 32KV), the motor will try to pull more and more current to start from the VFD, ultimately exceeding the current setting of the VFD and it will trip with an Overload or Overcurrent (OH, OC) fault on its display. If the current is enough to start the motor, it will rotate, but with very less speed (like if the motor is not connected to any load).
Just as a matter of interest, if you connect the LT side of TRF to VFD, and HT side of TRF to motor, "nothing" will happen as there is no current source (both VFD and motor are current consuming equipments) :P
Motor --> TRF HT -- TRF LT --> VFD (LOL!)
Is This Answer Correct ? | 1 Yes | 3 No |
Post New Answer View All Answers
how to increase senstivity of ct
generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...
which capacity of RCCB used for five thousand watt electricity load?
How can we connect additional batteries to three phase ups? What are parameters we have to check when connecting?
how to determine the cable size...pls explain me with the formula taking particular load....does the factors like impedance & short circuit rating influence the cable size, if so how....
thyristor controlled APFC panel design parameter?
Why we use 4-20 mA Analog signal for the PLC input? Why not 0-20 mA? Why not 5-25 mA?
Is it posible to instal one more SMDB from the existing SMDB and is it practical.
The efficiency of a 100kva transformer is 0.98 at full load as well as half load , for this transformer what is the Copper loss at full load ?
what happens if earth of 33kv cable is not connected to earthing pits? please send this query's answer to ngrm.sudha249@gmail.com
What is the drawback of class b amplifier? How is this minimized?
placing earthing pit in pathway is correct or wrong??. placing earthing wireGI1/18 inside walls is correct or wrong?. explain!!!
fuel-air ratio in a petrol engine fitted with suction carburettor,operating with dirty air filter as compared to clean filter will be
what is a pulse transformer? how rise time of pulse changes when ever the voltage changes?
how to electronic energy metter failed in electomagnectic fild passing in the metter and which thing to defect more on metter.