What will happen if id fan on boiler not functioning?.Can the
Boiler run without id fan? What is the effect?

Answer Posted / sheik nasir hussen

First of all Boiler willn't start without ID FAN due to Boiler interlock if by bypass this logic we start the boiler then draft can't be set without ID FAN Boiler will be trip with furnace draft high.if this logic also bypass then furnace will be pressurised before reaching required amount of air flow for combustion &proper combustion willn't occure which will damage the furnace tube and also there is a chances of furnace blast.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

some one can tell me how residual type excitation is provided through transformers to an AC generator without any battery or PMG&excitor

1948


What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?

1936


why do you consider yourself a suitable candidate for this position

6976


By any way can we increase the B check hours from 300 to 500

1695


why airtel use + 24 volts and other operators use -48 volt

2106






Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon

1765


what is natural frequency of turbine shaft .

1720


what's the moog valve

1050


our 125 kva DG does not start in AUTO mode works normally in MANUAL mode please give me a solution.....

1196


what is the trip circuit supervision in an electrical meaning?

1439


How to calculate power press toneage

1553


can u please tell me how to calculate the concrete quantity for a under reamed pile? r=300mm,depth=3m for a cylinder and for bulb l=.750mm,width=.525

1278


im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much

1474


Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.

2977


what is the difference between compensated & normal drum level in boiler drum?

1288