on 22.03.2015 at 17:15hrs Y phase 66kV class Power Trf-2 Current transformer has flashed over and oil came out. The failed CT has been replaced on 24.03.2015 at 13:15hrs and the Trf has been charged in presence of RT Hassan after conducting the pre-commissioning tests. On the same day at 17:00hrs the commissioned CT has again flashed over and immediately the Trf has been isolated from power supply. It is confirmed the secondary is not opened and checked the earth integrity and is found ok. Here what would be the reason for the CT failure?
Answer Posted / dheeraj.yadav
It may be cause due to meter internally circuit open the secondary of ct in meter.due to circuit problem.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
what are inductive and capacitive voltage transformers.what are their applications
what do you mean by type zero control sytem ?Give an practical example of type zero contol sytem?
Y phase plates are used in transmission line??? what is there need???
which is better to use svc or synchronous condenser why ?
what is the function of statics switch in ups and tell me parts
(1)The demand for electricity , the amount of renewable generation available, the amount of fossil fuel generation available and the cost of the fossil fuel generation are shown in table below period(hrs) demand(MW) renewable (MW) fossil- fuel(MW) cost of fossil fuel(MW) 00.00 - 01.00 2000 1800 2000 30 01.00 - 02.00 2300 2500 2000 30 02.00 - 03.00 2500 2700 2100 45 03.00 - 04.00 2900 3100 2100 50 04.00 - 05.00 2700 2600 2500 45 05.00 - 06.00 2400 2000 2700 50 06.00 - 07.00 2200 1800 2000 36 07.00 - 08.00 2100 1600 2000 36 Assuming that the renewable generation incurs zero cost, determine an optimal generation schedule(specifying the amount of renewable generation and fossil fuel generation used in each period, the cost for each period and the overall cost for 8 hours.)
Differentiate between kirchhoff’s first law and kirchhoff’s second law?
The 3 phase 400 hp 440 volt slip ring induction motor do not take one phase amps why ? The motor is running good condition
How a band pass filter is constructed?
How to check 11000/1.732 to 110/1.732 Potentila transformer (PT)?
What type of core material is used for metering C.T and protection C.T???
There are Two questions about Steam Turbine Generator... What is HRSG bypass of LP, HP used for in power generation? In particualar, in the event that fault of HP bypass, there would be STG TRIP in operation but none on the LP bypass fault...what's the reason ?
Different types of relay fault which phase sequence??
What is the difference in calculating size of AC cables compared to calculating size of DC Cables? Usually DC Cables are larger than AC Cables although they have the same ampacity. Why is it?
why do we not use equivalent voltage source in negative sequence equivalent ckt.