what,s the clear cover of beam,slab,column,lintel and
foundation?
Answer Posted / sandy
As per IS 456 2000
Slab-20mm
Beam/ Column-25mm or 2xDia of Main feinforcement.Which ever is greater.
Footing- Bottom 50mm
Footing side- 50 to 75mm depend on soil condition.
Pile - same as column.
| Is This Answer Correct ? | 1 Yes | 0 No |