if single phase is having 220v supply then why three phase is having 440v instead of 660v?
Answer Posted / gaurav kumar
in case of 1 phase the voltage is measuered between one phase wire and another neutral. And called phase voltage. Whereas in 3 phase line voltage is measured and used
| Is This Answer Correct ? | 4 Yes | 2 No |
Post New Answer View All Answers
Role of active and reactive Power sharing in between two synchronized Generators, Droop Setting role ?
WHAT IS SHORT CIRCUIT STRENGTH OF 100 AMPS MCCB?
As we use capacitor bank in 3ph ckt to improve PF, can we use capacitor in single ph domestric use, in house we have Fan,Mixer,electric cooker,iron,tube choke they also lag the system,because it is inductive load. if it is possible to improve PF of single ph system-- if yes- type of capacitor to be used,connection diagram, working in detail. if no-- list it.
why the active power flow of some line is increased when the active power of out is cut ?
What are the classifications of oscillators?
Can we Co-ordinate relay in Load Break switch?
what is the difference between unarmoured & Flexible cable? How to identified?
I don't understand why when we connect high voltage source in DC to electronic motor , we must add capacitor and resistor in parallel ? (I know that we use capacitor because we want to absorb the current that in the first second electronic motor in opposed with current course produce. ) what are the feature of Resistor and in such situation ?
What is the meaning of 40X8X2 busbar dimensions for carring load of 400 Amps
Can any one give an explanation about rating factors of cable? if we are laying the cable on the air with an temp 15 degree then rating factors will be 1.15 and if we are laying the cable on the air an temp 60 degree then rating factor will be 0.76 please describe it and what is the difference between rating factor and derating factor?
Help need in transformer !? Hello Friends The parameters of 2300/230 v 50hz t/f is R1=0.286 ohm R`2=0.319 ohm Rc=240 ohm X1=0.73 ohm X`2=0.73 ohm Xm=49.2 ohm Secondary Load impedance ZL=0.387+J0.29 solve the exact equivalent circuit with normal voltage across primery.. I know every thing but i cant find CURRENT I1=? and I`2=? Please help me give solution or only Formula please please...
What will be the effect of circulating current in HT xlpe cable when both the armour ends are grounded. Will the termination fils after some time in case of 33 kv supply.
While testing LA mast,What are the parameter limits ?
how calculated Transformer losses.