when we start the tube light, then it takes initially 1100
volt, after glow it takes 120 volt?(when we give 220 volt a.c.)
Answer Posted / pritish
at the initial stage the voltage induced by the choke is nearly about 2000v due to the inductive property of choke and this high voltage is required to discharge the gasses from the filament of the tubelight. after the discharge id initiated it requires normal supply voltage to maintain the path for the gasses inside the tube.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
can we use CBCT in neutral of solidly grounded transformer? in place of three phases we can pass only one phase which decreases the size of CBCT?
What is the role of Dedicated earthing in UPS System?
What is the type of earth fault protection used in battery? explain.
Where can i get practical knowledge of solar system?
Iin ESP why positive is grounded ? why not negative ?
how is the testing of an REF relay? what are the test REF circuit having?
What is the technical difference between On delay timer and a Star delta timer?
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING) I O (current operating)?
What is the RME and explain the full form and what is the RME work?
Where burned of electricity,when,who, & why.
how we calculate torque ? how we improve it ?where torque will either motor or generator ?
What is real time power factor control panel(RTPFC)?
Dear Sir/Madam, I have one questions we have three steam turbines and one Gas turbine and our industry linked with the public network, we have protection system one of the protection is reverse power we can export just four MW only i would like to ask about how to calculate the reverse power. Thank you in advance best regards
why are distributed windings generally used in alternators?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?