why do we use LPF wattmeter not UPF in the experiment of no load and blocked rotor test of 3phase slipring induction motor?
Answer Posted / pritish
in case of no load test, the supply voltage is rated but the current drawn by the induction motor is very less; no load current, which produces only the core loss of the stator and some mechanical loss. in no load condition, the angle between V and I are high as a factor the pf will be less. hence to calculate the pf accurately LPF wattmeter is used. during loaded condition current increases and angle decreases hence pf increases.
any more clarification regarding this should be sent to pritish.nath@gmail.com
| Is This Answer Correct ? | 36 Yes | 3 No |
Post New Answer View All Answers
What happens if we give the supply to the rotor of induction motor and make its terminal shorted?
How to decide CT & PT ratings for a given transmission line carrying some rated voltage?
Name the test signals used in control system
Explain Energy and Power signals?
how to test and calculat the head and discharge in borewell compressor
what is POTT and PUTT explain?
How to apply 'c' license and also explain what is difference between 'c' and 'b'license.i am also working in one of the private company.i have finished my diploma in 2014 .i have already finished in ITI electrician course.....
iam using DM 3251 voltmeter(1 percent accuracy)for 11KV system PT ratio is 11KV/110V.can anybody explain what is the max and min voltage deviation.
what is JE exam?
HOW TO CALCULATE EARTHING SIZING?
What is the tests required for a 132 kV, 400 kV , 765 kV for a Circuit Breaker and Power Transformer before commissioning ?
what is the synchronous timer ? and it applications.
what is v/f control in VFD?
In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes
Please brief me about number of pole in alternator.In single phase alternator coils are connected in star or series. How to calculate frequency for the same.