Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Simultaneous trip of incoming and outgoing breakers of
400kv/220kv trnasformer. What are the probable causes?

Answer Posted / raj kumar

Incomer side or outgoing side current transformer terminals connected wrongly by mistake.so reverse current will flow in the secondary.secondary is connected to the metering device and protective devices.so protective devices will sense the reverse current flow.if that current reaches certain level,this protective device trip the circuit breaker.
If both side CB's are tripping simultaneously means transformer winding side only fault happened.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is hipot test procedure?

1457


What we mean by vintage of an engine+Generator?

2119


How to select, design,size & calculate for 11 KV/33KV/66KV/132KV/220 KV/440 KV circuit breaker for HT side of transformer protection/HT distribution protection?

2754


What happen when neutral point connected to core balance current transformer? (Neutral point of an alternator of a 180KVA DG. Neutral point connected to CBCT means enter to the CBCT)

2275


what is the preventive maintence for ht panels and busbars and vcb abd acb's.

2365


we are having 15kw and 3kw motor both can run in same time , instead of using copper we are using ug aluminium cable , 35 sq.mm is suitable for its current carrying capacity..?

1731


please send me the L&T Emb. sys. placement papers and entire details of pattren

2324


what is PID control in VFD drives?

1992


What is the problem of internal failure in ship engine telegraph system norcontrol?

2392


What are the relays in ACB and VCB

2223


How to calculate earth fault current for 6.6 KV , 50 HZ , 756 Amps , 3000 RPM , 0.8 PF generator

2045


if a.c supply is given to the motor,, what happen?

2149


HOW TO WORK A VFD?SAY SIMPLE METHOD

4413


EXPLAIN THE WORKING OF SERIES REACTOR IN HT CAPACITOR BANKS (FOR VOLTAGES & CURRENTS)

8263


Why reactive power is needed in a power system? How is it being absorbed or delivered by alternators? For reactive power control we are changing excitation but reactive power absorbing or delivering related to stator. How these two are interlinked? i want a detailed explanation with necessary expressions and figures?

1900