What is chiral and why this performing in HPLC
Answer Posted / rajasekhar
Some samples have chiral centers . These samples cant saparate reverse phase columns and Narmal phase columns. We can saparate these sample only Chiral columns.Due to charal samples have Isomers, these isomers have same polarity and phisical property.
In chiral columns have one Isomer , which interacts with sample isomers differently , thats why we can saparate.
| Is This Answer Correct ? | 11 Yes | 2 No |
Post New Answer View All Answers
How to know the estimated LOQ concentration in ppm
in which situation ion pair require to use?
in each media we require to use SLS? how to proceed?
[3/30, 13:29] Manoj P Venkatpurwar: How hplc column selection according to structure? How mobile phase buffer selection on molecule structure?
what is the acceptance criteria for enteric coated tablets in 0.1n hcl validation in each parameter?
please explain about aluminium hydroxide assay
how to selecet an exact coloumn for an new molecule development by hplc how to select exact salt as buffer for new molecule development by hplc what is the the process to select the mode of saparation of compoundes by hplc what is the use of ph of buffer what is use of buffer,ph,organic phase,ans methods how the molecules get saparated in coloumn,
Why potassium dichromate is used in calibration of uv?
why require to add enzymes in capsules dissolution only? is it require to tablet also?
How can the GC or HPLC method is selected to determine the impurity profile in drug product?
what is mean by covalidation
in sampling of raw material which side is pasted sampled labels
In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?
I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?
Why acetonitrile and water are used as extraction solvent when analysis melamine? I thought they are miscible and won't be able to separate...