Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how to calulate multiplying factor if meter ratio is /5 ampere
and ct ratio is 100/5 ampere.(our supply is 3 phase 415
volts)what is multiply factor?

Answer Posted / sandy

if ct ratio is 100/5A then multiplying factor will be 20.

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Define reserve-generating capacity?

1170


what are the possible reaons & remedies if resistance of NGR getting heat up

1840


what is relation between ct and pt ratio with multiplication factor of a energy meter? is there any other factor on which multification factor depend?

2330


What is Scheme Test of High Voltage Switchgear. Which tests it includes.

2410


how to interlock 3 nos MCCBs using under voltage coil. please provide me circuit diagram?

2602


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1989


how can we change the phase angle b/w two phase?

5165


Explain what is use of lockout relay in ht voltage?

1074


Why we are use dol starter up to 10 hp

1366


why current is constant on d.c?

2084


what is the difference between electrical and electronic choke?

1955


how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

2211


How to calculate size of HT breaker with the help of Amp (current)? Please provide answers with examples.

2324


can anyone tell me can the electromagnetic waves can be reflected back?if so how &by which material it can be reflected back?please tell me so that it can help to my wireless power trasnmission device.

1796


1.what is the funtion of chiller primary & scondary pumps. 2.what is the use of distribution lines & Types. 3.what is the use the thermal power stations & how much capacity.

1974