what is hot loop check and cold loop check.
Answer Posted / vikaspanwar47
Hot loop check is power up checking .cold loop checking is continuity only.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
What is the purpose of the analyzer in petrochemical plant?
I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.
what is loop1 and loop2 in MTS LT?
What is three element drum level control system why its better than single element?
Working principle of magnetic flow meter ......and calibration procedure of e+h magnetic flowmeter...
why use 50% lel methane gas concentration for gas detector calibration instead of 60% lel gas concentration whereas the hi alarm set at 60% lel.
How flow can be measured with dp?
What is frequency factor in massflow meter? When using frequency output?
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
what is sil (safety integrity level
can we create an interrupt in plc through scada?
Why we are using DPT(Differential Pressure Transmitter) in separator instead of level trasmitter?
we are using centum vp as monitoring with Dell precision work station T3600 but some times PC(s) are restarted automatically . how we can solve this problem? thanks
I am using 971 Enraf radar level transmitter for LPG tanks ,the tank side indicator gives the error code 999999999FL can any body give me any diagnostic for this issue?
How will you calibrate an Absolute Pr.Transmitter of range 400mmHg absolute ?