Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is armature reaction?explain in simple words?and what
is its infleunce on dc motor

Answer Posted / rizwankhan

The action of armature flux on the main flux is called as armature reaction.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

which pump used in WTP explain the function of VFD how to dtermine capacitorbank of capacity one plant

1986


Can you tell me more about pu systems (per unit systems )calculation in large power systems? how to get the base for voltage and power in generator, transformator and transmission lines?

2344


Single line diagrams for star to delta and DOL starters.

2310


Do you know what is dry-out test in x'mer

2711


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

2205


what is the problem when i want to close a circuit breaker by local position it closes well.but when i close it in remote position it trips

1664


various transmission tower like .,D tower ,K.C.O tower ,C.C.O tower,K.C.R tower ,C.C.R tower ,H.C.O tower in different tons.

3373


Why field rheostat is kept in minimum position while armature rheostat at maximum position?

1168


Why we make earth connection with Transformer Body and What will be the minimum size of copper wire as per code with respect to KVA rating of Transformer?

1869


Define what is difference between fuse and breaker?

1237


Which type of a.c motor is used in the fan (ceiling fan, exhaust fan, pedestal fan, bracket fan etc) which are find in the houses ?

1083


What is the best thing to protect the motor from running over full current. CT or O/L or pressure transducer at the given pressure rating

1592


If mutual flux is 1.2wb & power factor is 0.8 lag , then what is the Useful flux of a transformer?

4549


What is the difference between cylindrical-type and sandwich-type winding?

1514


how to test the turn ratio of 3 phase transformer using volt meter shoe the curcit diagram.

2507