HELLO FRENDS ,, I M IN THE MIDST OF TROUBLE .. JUST LITTLE HELP ME...

SUPPOSE ,, I HAVE A CLOSE VESSELE TANK ( HEXANE MEDIA ) ,,

I M USING ROSEMOUNT 2051 DPT FOR LEVEL APPLICATION ..

ITS CALIBRATE RANGE IS.. . 0 TO 950 MMH20 ..I DID CALIBRATED DPT WITHOUT
REMOVING IMPULSE LINE OF HIGH AND LOW TAPPING.. & WITHOUT DISTURB 3 WAY
MANIFOLD..!!!

BUT ,,, DURING CALIBRATION I SELECT RANGE BY HART LRV IS 900 MMH20 & URV
IS 1300 MMH20 ,, BUT ,TANK LEVEL SOMETIMES 100 % AT 1100 MMH20 ,
SOMETIMES 1300 MMH20 ..IN THIS CONDITION .. WHOLE LOOP FAILED ,, MAIN
THING IS THAT ,, HOW TO CUSTOME RANGE SELECT ?? AND IF I USED RANGE OVER
THE ORIGINAL CALIBRATE RANGE ,,,THEN WHAT ERROR WILL BE COME ??? HOW TO
ZERO CALIBRATION OF DPT... HOW TO ZERO TRIM BY MANIFOLD ?? AND FOR TANK
LEVEL PURPOSE ... WHICH UNIT I CAN USE ??? IS THERE ANY CALCULATION OR
CALIBRATION .. IF YEH .. THEN PLZ JUST GIVE ME CALIBRATION STEPS FOR DPT..

THANKS YOURSSSSSSS

Answer Posted / carl_ellis

There is insufficient information to determine what the
correct range of the transmitter should be.

1) Is there a capillary with remote seal on either side of
the DP xmtr? If so describe in detail.

2) Is the DP xmtr mounted directly on the lower flange? If
not how high above and below the lower flange (tap) is it
mounted?

3) Is the DP xmtr high side connected to the lower flange (tap)?

4) Is the low side a dry leg or wet leg?

5) What is the specific gravity of the material in the tank?

6) If the low side is a wet leg, what is the specific
gravity of the fill fluid in the wet leg?

7) What is the elevation distance from the lower flange and
the maximum level?

8) what engineering units are used for level ? mm H2O?

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I want to know the questions asked in ONGC interview(after being selected in the written exam) for Instrumentation branch.Kindly help.

1776


What is the cascade control

998


Why flow/pressure transmitter before control valve?

1074


what is gas metering system? gas chromatograph? and gas compressors?

1974


What is zero elevation and zero suppression?

1614






Explain Gas Turbine startup and shutdown sequences

3829


Why plc require in analog input 4-20amp & 0-10 volt?

632


What is the GK Value in Flowmeter?

3069


Reason for capillary type dp level transmitter fluctuation

1531


If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , so what to do for solve this problem. The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?

1641


installation process of orifice,a question asked for confusion creation in interview by BARC 1.if orifice is tightly fitted with pipe ,it will act like venturi 2.if orifice is left hanging in between liquid it will not create the pressure difference exactly,

1678


what is easiest way to read STL language in PLC?

2672


explain key exchanges in all security modes WPA,WPA2,TLS?

1509


What is the use of double seated valve?

744


How many interlocks at turbine side?

1446