Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

HELLO FRENDS ,, I M IN THE MIDST OF TROUBLE .. JUST LITTLE HELP ME...

SUPPOSE ,, I HAVE A CLOSE VESSELE TANK ( HEXANE MEDIA ) ,,

I M USING ROSEMOUNT 2051 DPT FOR LEVEL APPLICATION ..

ITS CALIBRATE RANGE IS.. . 0 TO 950 MMH20 ..I DID CALIBRATED DPT WITHOUT
REMOVING IMPULSE LINE OF HIGH AND LOW TAPPING.. & WITHOUT DISTURB 3 WAY
MANIFOLD..!!!

BUT ,,, DURING CALIBRATION I SELECT RANGE BY HART LRV IS 900 MMH20 & URV
IS 1300 MMH20 ,, BUT ,TANK LEVEL SOMETIMES 100 % AT 1100 MMH20 ,
SOMETIMES 1300 MMH20 ..IN THIS CONDITION .. WHOLE LOOP FAILED ,, MAIN
THING IS THAT ,, HOW TO CUSTOME RANGE SELECT ?? AND IF I USED RANGE OVER
THE ORIGINAL CALIBRATE RANGE ,,,THEN WHAT ERROR WILL BE COME ??? HOW TO
ZERO CALIBRATION OF DPT... HOW TO ZERO TRIM BY MANIFOLD ?? AND FOR TANK
LEVEL PURPOSE ... WHICH UNIT I CAN USE ??? IS THERE ANY CALCULATION OR
CALIBRATION .. IF YEH .. THEN PLZ JUST GIVE ME CALIBRATION STEPS FOR DPT..

THANKS YOURSSSSSSS

Answer Posted / carl_ellis

There is insufficient information to determine what the
correct range of the transmitter should be.

1) Is there a capillary with remote seal on either side of
the DP xmtr? If so describe in detail.

2) Is the DP xmtr mounted directly on the lower flange? If
not how high above and below the lower flange (tap) is it
mounted?

3) Is the DP xmtr high side connected to the lower flange (tap)?

4) Is the low side a dry leg or wet leg?

5) What is the specific gravity of the material in the tank?

6) If the low side is a wet leg, what is the specific
gravity of the fill fluid in the wet leg?

7) What is the elevation distance from the lower flange and
the maximum level?

8) what engineering units are used for level ? mm H2O?

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Can anyone send most commonly asked interview question in Oil & Gas industry

2257


what is wave length were using ?

1900


If P will increase then what will happen with PID?

6065


why micro controller 8051/52's clock frequency is internally divide by 12 ?? and why it is further divide by 32 in UART serial communication ??

7559


wich is coming the first HAZOP OR SIL

2762


How to decrease opening & closing time of on/off valve?

1510


How addressable fire systems work? Pl. send details with architect.(Loop), also send details regarding Gas system. Pl. help me.Thanks

2104


How to calculate mmwc values into tonnes?

1259


What is Cavitation in a control valve?

2065


What is standard of DCS panel design?and what is step of DCS panel design?wiring and type of connector(screw or DB connector)

2111


any one can send me instrumentation previous interview papers? I prepare for MNC Company Interviews? my mail id- Rakesh.Golla@dodsaldxb.ae , and another mail rakesh.gvk@gmail.com

1960


whats the abbreviation of IOP? is it instrument of power or input open problem?

1171


selection of the zener barrier for the hazardeous area zone 0

2260


what should he know if he is an assitent engineer instrumentation in cement industries of experience of 10 - 15 year.

2097


is motorized valve closed when power shutoff?

1734