Answer Posted / sheikh
Neutral is a part of any current carrying circuit it means
every one alive circuit completed the path via neutral wire,
earth is not a part of any circuit frequently used as a
protective means to avoid electrical shock.
Is This Answer Correct ? | 4 Yes | 2 No |
Post New Answer View All Answers
How to setting the volume of RTCC panel AVR (11kv) controller
What is the formula for calculating the Instantaneous Short Circuit & overcurrent for any breaker
Is it required to use Automatic transfer Switch in L&T panel board if we use AMF panel with DG set? How the single line diagram will be? Please forward the material to sreenu_207@yahoo.co.in
hi friends how 3 phase converter functioning ?what is working principle of rotory phase converter ?
Difference between earthing & grounding.?
explain why core loss of a transformer is almost constant under different load conditions when connected across a constant voltage and constant frequency.
the site measured knee point voltage of protection class CTs should be greater than rated knee point voltage? what about meetering class CTs. Should it be below the rated knee point voltage?
how we can find of current direction(supply comming/out going direction) when a transmission line passing through sides.
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
What is essential to prove safe isolation of electrical circuit?
What are IP protections used for electrical panels, JB, equipments installed in explosive zones like Petrochemicals, Oil & gas
What we mean by vintage of an engine+Generator?
if main CT is of ratio 50/5, and meter CT is -/5 what will be overall multiplying factor of meter.PT is 11000/110 .
What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.
what is the most permissible winding temp when we conducting a generator load test?(condition no load)