Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What will happen if id fan on boiler not functioning?.Can the
Boiler run without id fan? What is the effect?

Answer Posted / vellaisamy

if ID FAN ON BOILER NOT FUNCTIONING, FURNACE PRESSURE WILL RAISE AND BYPASS DAMPER WILL OPEN IMMEDIATELY ASPER THE BOILER'S SAFETY INTERLOCK EXECUTION.SO THAT, THE BOILER WILL BE SAFE, WHERE AS BOILER EFFICIENCY WILL BE LOW BECAUSE OF NO HEAT EXCHANGING IN THE COMBUSTION AIR AND FURNACE DRAFT ALSO WILL NOT PERFECT.HENCE BOILER CAN RUN WITHOUT ID FAN WITH LOW LOAD.

Is This Answer Correct ?    9 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why do you consider yourself a suitable candidate for this position

7379


dear sir i have completed one year post diploma certificate in thermal power engineering from national power training institute durgapur ...plz suggest me for power sector job

2488


How We Calibrate the vaccum transmitter?

1923


what does mean by kva rating

1440


some one can tell me how residual type excitation is provided through transformers to an AC generator without any battery or PMG&excitor

2347


how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?

1651


why airtel use + 24 volts and other operators use -48 volt

2564


what's the moog valve

1434


What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?

2371


what is natural frequency of turbine shaft .

2223


explain how the third harmonic content of the magnetising current affects transformer design

3203


Why superheated are started before I'd and rd fan?

2117


DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.

941


What is LB-SR.

2949


im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much

1932