Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

if RTD damage in plant, how we know?

Answer Posted / md gulfraj alam

sorry sir my english is touch week .. first take a multimeter and set in resistance mode and measure the rtd.if 100 ohm resistance at 0° centigrade then rtd pt-100 is ok near value 99-101 ohm resistance.and same case in pt50,pt25,pt500,pt100 etc only value is isolated of all rtd.otherwise rtd is damage when not match the value..i hope u understanding my ans.thank you

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Give 2 application of quartz crystal used for process parameter measurement.

1969


1)How many tpes of vibration probe and how many tpyes of vibration. 2)how we can calibrate a vibration probe with tk3 3)what is RMS value in vibration measuring application and how we calculate it.

2366


what is easiest way to read STL language in PLC?

3084


how will you segregate the alarm levels in alarm management system during factory Acceptance Test

2318


please tell me what is a light up procedure of Cfbc boiler and what it's axuillaries of cfbc boiler?

8611


Instrument QA/Qc what is the project quality plan?conduit inspection RFI. which documents attache with package?

10791


Specify eight technical requirements that you would consider important, when deciding upon a particular control valve?

1822


what is performance test.need defination

1660


what is maxdna ?. explain about the software details.

4314


Which type of diaphragm use in costic line, dm water line, natural gas line, oil line?

1103


Why all the drains(Gland sealing,ESV,Casing inlet etc) are directly connected to the flash tank instead of hotwell of the condensor in the power plant? My Email Id:naba02222@gmail.com

2239


1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling

2375


Can anyone convert a 5/2 way or 3/2 way valve into an ISO valve?

872


For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?

5399


How do you identify between actual alarm and false alarm in a Temperature Transmitter in SCADA based Control System

1302