What is AVR? Explain the function AVR?
Answer Posted / rama kishore karri
AVR is an automatic voltage regulator. The function of AVR is to keep the terminal voltage constant as load variation on power lines. Moreover, the output voltage variation is more likely to be severe because changes in the load power factor. For example an alternator AVR changes the alternator field current to compensate for either increase or decrease load voltage. A controller is used to increase or decrease the field current through field circuit. As the AC voltage falls field controller circuit causes to increase the flux and thus induces increased voltage and vice verse
| Is This Answer Correct ? | 7 Yes | 5 No |
Post New Answer View All Answers
In Power Line Communication (PLC) the wave trap is used to block communication signals from entering neighboring lines. My question is this: Why do they allow for different filtering arrangements on these wave traps? Isn't it always going to be a low pass filter since we want the power frequency to go through, and the comm signal blocked?
In a voltage-controlled current source A A current booster is never used B The load is always floated C A stiff current source drives the load D The load current equals Isc
whether fibre optic cable in high voltage earth conductor is used for protection circuits
What would cause a 240v choke that should give 110v out on a 16w lamp to gradually increase to 160v?
What are the uses of lead compensator?
what is the ckt diagram of a tubelight and is it the simplest ckt of electrical engineering and also the component?
If anyone would like to know or practice for FEWA papers contact me on mohamedrashad2@hotmail.com Just completed the supervisor exam in April 2021
what are the different sizes of U.G. cable & where these cabl;es are used according to voltage ..
What is the two pole structure?
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
why any centrifugal blower draw more current in starting. consider id fan and fd fan?
HOW TO CALCULATE THE REGULATION OF 100 AND 25 KVA TRANSFORMER
What is nichols chart?
What is the abbreviation of NGT panel
How can i get my certificate of competency as an electrical supervisor? I have complicated my B.Tech from Uttarakhand technical university this year (2012).