What is the role and reponsibilities of Electrical
Engineers in construction field?

Answer Posted / mariappan

• Study of drawing and execute the work
• To co-ordinate with Electrical Contractor for Electrification, Execution, Erection & Commissioning.
• To provide the entire electrical solutions as per requirement.
• Design for illumination of different area and lux calculation.
• To check the entire work as according to approved drawings.
• Handling of electrical load as per requirement.
• Cable size calculation cable scheduling &its route selection ,over head or under ground.
• Review Inspection and Test Plans in order to perform all required inspections and witnessing all required tests and add witness and hold points for the Client’s Inspection.
• Review inspection reports and records of Quality Control carried out on completed and running Project activities.
• Review Client’s Inspectors deliverables, analyse and resolve issues and problems emerging during the Quality Control activities. Ensure that all inspection and tests witnessed by clients
• Drawing submission and get Approval from consultants
• Site issues highlighting and send to consultant
• Site Additional work Prepairation and send the Quotation
• Check and Plan the EOT Date & schedule of the Project
• Every two week once attend the site technical coordination meeting
• Monthly once attend the site safety coordination meeting
• Detail engineering with safety factor in the design.
• Updating the Drawing depends on site condition
• Mock up unit Prepairation and execution
• Checking the Workmanship and material Quality as per approved make and standard work for the Right quality and standard work
• Daily & Weekly work Progress Report Prepairation and Keep the Record
• Preparing the Monthly work Progress Report for Claim with Measurements
• Monthly LEW Tools inspection check list Prepairation and checking
• Daily I conduct and maintain the tools box meeting and checking the Height work Permit (above 2m)
• Preparation of Project Report for correct and Timely information for the Progress of work
• Responsible to do surveys including site measurements
• Responsible for Highlighting foreseen Problem & Delays in advance Escalating to the PM
• Client communication and correspondence
• Quality Assurance
• Coordination with workers
• Manpower Controlling and solve the Problem
• Updating of material stock
• Weekly Material Requirement to be send by email to office
• Final Documentation & Billing Works

Is This Answer Correct ?    58 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how cables go in and come out for distribution from the feeder pillar box?

1702


Name of the relay of low lub oil presuure in DG sets

1685


In EHV transmission line a neutral grounding reactor is often placed at neutral point of shunt reactors. What is the recommended protection for this neutral grounding reactor? Should I use a fast closing switch to bypass neutral grounding reactor when this protection operates?

2861


Types of test in Switchgears, MCC, NGR and DB's how it should be procced. Can anyone give me the details here or email me to pasuvaraj.k@gmail.com

1729


how are reversing the direction of dc motor

1285






it is possible to rotate the DG engine dc starter with wrong polarity connections? why?

1849


Define resonant peak?

754


how rectifier transformer work in electroststic precipetatore(esp?

2190


can you any one give exact mathematical relation between AC current and DC current?

1511


how to setting Load amps tripping time and extra settings for load Transformer protection relay with RMU panel using C&S model relay..?

695


Why the efficiency of a three-phase induction is the motor is less than that of a three-phase transformer?

808


Does the direction of rotation of d.c. Shunt motor would get reversed if the armature current and field current both are reversed?

758


What kind of Neutral CT can be placed in 11/0.433KV transformer to be used and what are its specification?

1539


defination of lines

1639


Alternator rotor earth fault relay circuit

1670