how many safeties should be present in boiler?what are they?
Answer Posted / bhola shnaker
there are 2 to 6 numbers of safety valves (SVs) on the boiler.
Around 2 Nos on Drum, of one high and one low setpoint.
Around 2 Nos on Superheater Steam Line of one high and one low setpoint.(but less then Drum SV setpoint, to avoid starvation of SH main steam line)
around 2 Nos on reheater line (if reheater is provided)
Apart from it 1 No of EMRV on the HP superheater line, setpoints below that of Safety valves of the lines.
Also we have Relief valves on he HP econimiser, which acts as a Over protection valve (against Pressure)
Remember SVs are Differnt from Relief valves, as RVs are used on liquid whereas SVs are used on Steam line.
Is This Answer Correct ? | 11 Yes | 0 No |
Post New Answer View All Answers
why do you consider yourself a suitable candidate for this position
We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?
what is the basic use of power plant in equipment
Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon
Why superheated are started before I'd and rd fan?
Which will have more strain energy 1.Spring 2.Circular disc 3.Solid square plate.
LAPT working in alternator / generator
how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?
What is LB-SR.
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.
what's the moog valve
what is restricted earth fault explain in details
some one can tell me how residual type excitation is provided through transformers to an AC generator without any battery or PMG&excitor
What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?
procedure of how to generate power in solar plant.