Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What impact analysis required for out of calibration and
how to proceed

Answer Posted / murali reddy

We have to 're check why it has failed.For example wavelength accuracy failed means we have to do impact analysis
That is before calibration of HPLC ..Which products are analysed
The same products (same test) had to repeat on another system
Like this last 5 samples need to analysed.if results are ok
We can say no impact.Then after knowing actual problem
Re calibration required n proper justification should be given.

Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is related substance by HPLC impurity limits as per USP?

1096


why holium oxide prepared in 10% HCLO4 SOLUTION

1450


is it nessesary to do solution stability for 7 days?

765


Which is the highly polar and highly non polar column in HPLC?

2297


How to do regeneration of Metacarb Pb plus column?

2574


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3532


what is the structure of DOWEX-50

5503


How to compare XRD graphs against standard and carry polymorpism study of API's by powder XRD method?

3859


While performing TOC sst analysis Zero shift disabled & sample analysis zero shift enabled why?

2854


How to calibration of the uv spectroscopy and its test?

1189


In rs method development when we are going area normalization method to dilute standard method?

1516


what is the origin to prepare standard operating procedure

2315


Why do we use KMnO4 in the test of control of obsorbance ? and why do we take specific quantity i.e 57-63mg?

2823


how to calibrate hplc & gc

4500


How they found 1mL of K.F reagent is equivalent to 5mg of water and if we change the composition of K.F reagent, is it can neutralize more amount of water?

1767