What is the use of starter in tube light fitting.how it works.
Answer Posted / jvino03
Initially Tube light need more voltage during starting time
to get ionization of electrons. So the purpose of Stater is
to flicker or excite the tube light with high voltage,
Stater is nothing but a 2 metals which is in contact during
starting purpose only... After it comes out from the
circuit....
Is This Answer Correct ? | 8 Yes | 2 No |
Post New Answer View All Answers
what is diff btw electric,magnetic & eletromagnetic field
How does zener phenomenon differ from avalanche breakdown?
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING) I O (current operating)?
which model T or pie model is prefarable in power syatem
What is the main cause of magnetism?
Is it possible to operate a synchronous 2-poles turbogenerator with a still-in-place faulted bar but electrically disconnected ???? If yes, should I act on the other phases as well ???
What is the most essential condition for the voltage build up for a d.c. Shunt generator?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
Comparision of Air break circuit breaker, SF6 Circuit breaker and vacuum circuit breaker.
XYZ
Why are the laminations insulated from each other?
how was your last weekend.
WHAT IS MOBILE SUB-STATION? & REALLY BENEFIT IN INDIA
Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.