why dc series moter is not started at no load?
Answer Posted / abhishekkumar
Motor armature current is decided by the load. On light load or no load, the armature current drawn by the motor is very small.
In case of a d.c. series motor,
Φ α Ia
and on no load as Ia is small hence flux produced is also very small.
According to speed equation,
N α 1/Φ as Eb is almost constant.
So on very light load or no load as flux is very small, the motor tries to run at dangerously high speed which may damage the motor mechanically. This can be seen from the speed-armature current and the speed-torque characteristics that on low armature current and low torque condition motor shows a tendency to rotate with dangerously high speed.
This is the reason why series motor should never be started on light loads or no load conditions. Foe this reason it is not selected for belt drives as breaking or slipping of belt causes to throw the entire load off on the motor and made to run motor with no load which is dangerous.
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
what can be the causes of capacitor start motor having a higher current that its actual
Can u Explain about the electronic trivector meter and the use of data converters in them?
hr round
A ii kv 1200 A Breaker combination fixed in a cubicle. How many ampere Fuse is required? If fuse is not using, Why?
Can we test the alignment of End shield and stator of turbogenerator without rotor insertion? Also how to fix maintain the alignment at site installation?
State how to produce a constant rotating field by application of alternating currents to stator armature of a three-phase squirrel-cage induction motor
what are the different sizes of U.G. cable & where these cabl;es are used according to voltage ..
What are linear and non-linear systems?
What is the slip speed?
why three phase capacitor takes unbalanced current in capacitor bank?
how can motor both beasrings insulation resistance can be check?
How many capacitors using in LT panel as per Govt rules?
What should be the length of transmission line so that we can see/obtain the full sine wave of voltage??
what is the difference between oil surge relay and buchholz relay.
I PURCHASED A DEISEL GENARATOR SET OF AVR TYPE& RATING 125KVA BUT SOME TIMES THE OUTPUT VOLTAGE IS FLUCTUATING WHAT ARE THE PROBABLE REASONS GIVE ME