Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the diff. b/w restricted earth fault relay &
standby earthfault relay and where they are used?

Answer Posted / hari

REF is a kind of protection that is connected to the Star Wnding CT which has a neutral connection.It covers only the protection of restricted regions like windings,breakers & cables.

Wherein SBEF relays are connected to the Star Windings and it detects the Zero sequence current in the neutral CT's.

Is This Answer Correct ?    1 Yes 15 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Form S and "c" license application both are same? @ tneb portal

1846


I have one ct of ratio 3000-2000/1 Amp its knee point voltage mentioned on name plate is 500-333/30mA-50mA at Vk/2. in secondary box there is three terminal named 1S1, 1S2, 1S3 then on which terminal obtained the knee point voltage ie 1S1-1S2 OR 1S1-1S3 & also specify the knee point voltage for the ratio 3000 from name plate.

2454


Explain the experiment on ward leonard method of a speed control on a dc shunt motor with an suitable circuit diagram.

2596


i have a 4 Mva transformer 34.5 kv / 480-277 v and i used 2 parallel 3200 amp bus duct for the secondary feeder using 3 ply of bus bar ( 3/8" x 5" ) as a common where the flexible link terminated and 6300 amps breaker for the main, the lower bus duct reaches 70 degrees and the upper bus duct reaches 55 degrees when i used thermal scanner. why the temperature is not balance when the load reaches 3600 amps.

1928


for hipot test on 33kV busbar, we will test on 70 kV or 56kV, what is the acceptable leackage current?

1167


Approach of a cooling tower is the difference between temperatures of what factors?

1155


hi friends how 3 phase converter functioning ?what is working principle of rotory phase converter ?

2104


relation between power station capacity and voltage level?

2061


Is RTCC panel needs any control supply.

2062


why would the rotor rotate at sub synchronous speed against the direction of rotating flux when d rotor of 3 phase IM is connected to 3 phase balanced supply and the stator windings are shortcircuited ??

2043


what are the main applications of transistor in non-linear region?

2057


Explain The Application Of Storage Batteries?

1154


how could we calculate the no of outgoings from a 800 watt distribution board

1828


can anybody send me syllabus of rrb section engg (electrical). and also send previous question pepar...

1990


why we are using Load factor?

1962