Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

two transformers of the same type, using the same grade of
iron and conducting material, are designed to work at same
flux and current densities, but the linear dimension of one
are two times of the other in all respects. The ration of
kVA of the two transformer closely equal to................?
options: 16, 8, 4, 2

Answer Posted / 7anoter4

According to Rudolf Richter “Electric Machines” vol III
Transformers the rated apparent power will be n^2 times this
of the smaller dimensions [So]:
Sn=n^2*So that means for twice in dimensions the rated could
be 4 times the rated of the smaller.

Is This Answer Correct ?    17 Yes 29 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What will be the diameter of pipe between conservation tank and transformer

1922


what happens when series resonance occurs?

1843


What is different between Difnit time and instatous over current relay

2543


What is the role of feedback in a closed loop control system?

1072


what is level 2 automation?

3148


what are safety measures in /control in diesal engine/ explain them?

1786


how is the connection of a 3 phase ct trivector meter done on a pole mounted transformer

1356


when we have to purchase the transformer by own i.e how much load will preferred HT connection?

1667


Mention how NPN and PNP transistor works?

1280


What is meant by Im=30mA@Vk/2. How to know the kee point voltage for CT design

3448


What is the settings of distance protection relay in 400 kv line

1684


what is parellel power factor correction?

4386


ii) A shunt motor supplied at 230V, runs at 900 rpm when the current is 30A. The resistance of the armature is 0.4 ohms. Calculate the resistance required in series with the armature to reduce the speed to 600 rpm, assuming that the armature current is then 20A. [12]

2347


how to check regenerative load in drived motor

2226


Safety of on line ups

1940