Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What are the causes of high alkalinity in boiler water?

Answer Posted / chanakyapitti

PH of water will indicate the characteristic of water. Normal water has ph value 7, weather it will decrease the water change as acid.If it will raise above 7 the water will change as base. Further raising of ph above 10.2 it will leads the caustic embitterment. This will form in inner surface of boiler tubes as scale which was heat resident. Due this scale the heat transfer rate will be decreased by increasing the layer thickness in the tube. Overheating of tube will occur. because of overheating tube will be damaged. so that boiler water PH should be with in limits between 9.6-10.5

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

about induction motor

1997


how to calculate bearing pre-load?

3060


why to work in oil industry

1940


why does polytropic efficiency of a compressor decrease with increasing flow rate ?

2563


Instead of having individual transmission what is the benefit of unified transmission?

4944


How to Track the Inventory Items that are avaliable past 15years.

2020


What is gravity Dam? What are the forces causing stability?

1113


all mrf company details

2200


What is the most economical spacing of buttress ?

1375


Hai, iam renjith. my qtn about the calorex heat and cool pump. What is the reason of the above machine is trip on high pressure. r134a gas using in this system. 8 months old. model is calorex propac 90(3 phase). This system has 2 compressor. Both are starting on 13amps after that rise up to around 21 within 1 minute. After will be trip on high pressure. Showing 68 psi in suction side on standby mode. Can i have a solution without delay? Renjith renjithngm@gmail.com

2150


sir,i appllied junier engineer engineer in rrb chennai,i need syllabus for the topic of apptitude,reasonong,general english and mechanical engineering,and general studies.please sent my mail id aravindaptc@yahoo.co.in.

2167


effect of temperature on stainless steel,aluminized steel,chromium at (500C-750C)-required for project work on silencer 1.thermal conductivity 2.heat conduction 3.mechanical strength 4.temperature to weight ratio urgent

1854


Will going from a 3 tap to a 6 tap increase water pressure?

1079


sir, i need some help by you. sir i want to know there are any industry that give six month training on the basis of entrance examination. sir if there are any .pls send me ans on my email-id sk12005@rediffmail.com pls.

2050


What is a feed water pump? Dearator feed heater?

2129