In UPS, battery connections if parallel connection given,
what will happen?
Answer Posted / hari prasanth
Batteries connected in series:
Let us consider that we need to light a lamp of 24 V.
So we can use 4 six volt batteries which can be connected in series to constitute 24 V.(4 batteries * 6 V =24 V).
Advantage:
Batteries connected in series provide higher voltage with same capacity.
Batteries connected in parallel:
Consider the same scenario.
If four 6 V batteries are connected in parallel it will provide 6 V only.Also any any one is damaged (short circuited) it will become 0 V.
So it is mandatory to get 24 V battery.
Advantage:
Batteries connected in parallel provide same voltage but double capacity.
Posted by Hari Prasanth.G
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
WHICH SIZE A.B.CABLE IS USED FOR 11KV.
working principle of oil startar
mccb service sittings be done?
we have consol make 3 phase servo stabilizer for cnc m/c. while installing the earth neutral voltage is 1.7 volts at stbilizer off condition and when stabilizer get on en voltage reaches 4.8 volts (new earthing is done and neutral is helthy condition all phase to neutral volts 440,442,441 v)why this happen.solution for cause.
What are the uses of stepper motor?
explain single phase series motor
How to calculate earth wire load by formula
Currently what is the highest capacity (MVA) of SPPg generator available in the market?
How can I model an open-delta ground transformer for a network supplied by 4 unit GTG and power transformer in ETAP?
State the formula for overall efficiency of thermal power station
I AM FROM ELECTRICAL ENGINEERING ? I AM ASPIRING FOR "BHEL".HOW I HAVE TO PREPARE .ON WHICH TOPICS TO BE CONCENTRATE MORE.PLEASE GIVE FULL DETAILS OF WRITTEN EXAM.
what is the difference between directional & non directional earth fault with example please explain.
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
Brushes are placed at magnetically neutral axis,when brushes reach that point,the armature conductor gets shorted,but it can be seen that the dc supply is also shorted,wont that get damage? help me plz
from which subjects most of the technical que will b asked for hpcl(electrical).pls help me