Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In Megger which types of test we can do ? and How it works? How to use?

Answer Posted / nandagopan

for 3 phase motors megger is used to test the insulation
resistance of motor winding.phase to earth(winding to body)
must be greater than 1 mega ohm.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...

1931


Why only sinusoidal ac voltages are generated?why not triangular or sawtooth?

2098


How do we calculate transformer oil in liter from the rating of the transformer.

1676


How can we checked Killo Watts of Motor & Alternator?

2157


All the socket in a room become very hot, the Wall was also became very hot and the earth conductor also became live, what in your view might be the possible causes?

1660


how to find ratio of CT & PT in 66/11kv 12 mva supply system ? explain with calculation.

2416


I need the recommended size for a 3 phase transformer at 13.8 KV Primary and connected loads of 3000 kVA at 4200 volts and 2375 kVA @ 480 volts AC.

2035


The Q-facr o of a coil given as wL/R. what will be shape of Q versus frequency graph.

2026


DG SET BLOCK DIGRAM

2298


why a tester wont shock while testing the power in house

1861


How RTCC panel is working and give single line diagram for RTCC with transformer?

3115


why magnet has north and south poles only why not east and west and why we are considering as north and south poles? why cant we consider as east and west?

2042


What is a feedback in control system?

1218


TELL ME WHAT IS INDUCTOR AND CAPACITOR WHAT IS IT BASIC OPERATION ANDFUNCTION?

2023


what is effect of leading power facter on the system and billing

2345