how we can convert 3 phase to single phase without using any transformer
Answer Posted / kaniyamuthan
OK I ACCEPT THAT WE CAN TAKE SINGLE PHASE WHILE CONNECTING ANY ONE OF PHASE AND NEUTRAL.BUT IF IT IS A DELTA SUPPLY MEANS? AND ALSO ONE PROBLEM IF WE ARE TAKING THE SUPPLY FROM ONE PHASE IT WILL GET OVERLOADED (UNBALANCED).
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
if negative of DC supply used and positive is grounded through EGB, and if ELCB used in the system then is it sense the positive volatge and get tripped is it possible?
if i am in front of transmission line how to know that current direction without any equipment
Explain how you intend to work under pressure to meet up with deadline target?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
WHAT IS MEANT BY OVER EXCITATION IN GENERATOR TRANSFORMERS? DESCRIBE IT.
On Which Pressure PRV is operated.
is it possible to say motor horsepower number without seeing name plate(when name plate damaged)
Sir pl provide 5 year sample paper for post junior engineer(electrical).I have currently applied for junior engineer (electrical) on RRB Ajmer
11kv/433v delta/star distribution transformer primary side full load Ht current is 83.33A in , but input side VCB rating 800A.why?
A 100KVA SINGLE PHASE TRANSFORMER 10000/200V,50HZ REQUIRES 300V AT HV SIDE TO CIRCULATE FULL LOAD CURRENT WITH LV SHORT CIRCUITED.THE INTAKE IS 1000W.THE % OF REGULATION ON FULL LOAD AT 0.8 PF LAGGING WILL BE HOW MUCH AND THE SECONDARY TERMINAL VOLTAGE ON 0.8 PF LEADING WILL BE
What are the main advantages of bode plot?
1) Explain why we don't link the two earthing system ht and mv on a pole mounted transformer sub-station.
i have interview in Pepsi company what type of question will ask please send the question and answeer
How I calculate the ELCB for circuit breakers?
difference between ac series and parallel circuit