We have 132KV/11KV Grid connected power transformer for
getting power from Grid. Can we use this transformer for
sending generated power as well. I mean step up from 11KV to
132KV and transmit.

Answer Posted / yassir

yes we can but incase the frequency is the same for
generator and the grid.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the basic use of power plant in equipment

1225


what is natural frequency of turbine shaft .

1715


im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much

1470


We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?

1423


Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon

1763






DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.

510


How to calculate boiler capacity? I have 1 Autoclave, Which has to use for AAC block. Dimension for this Autoclave is - 13 Meter Length & 2.2 Meter Diameter.

1822


our 125 kva DG does not start in AUTO mode works normally in MANUAL mode please give me a solution.....

1190


can u please tell me how to calculate the concrete quantity for a under reamed pile? r=300mm,depth=3m for a cylinder and for bulb l=.750mm,width=.525

1273


Which will have more strain energy 1.Spring 2.Circular disc 3.Solid square plate.

1878


How We Calibrate the vaccum transmitter?

1463


some one can tell me how residual type excitation is provided through transformers to an AC generator without any battery or PMG&excitor

1946


What is difference between secondary Air & Tertiary Air and Their use.?

1469


What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?

1927


What is LB-SR.

2479