Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how to find total current when kva is 30.4 given ? should we
use root 3 (1.732) in the formula?

Answer Posted / arumugam

can someone answer me the formulation how shri arrived the formula for A=kva*1000/(v*1.732.how does 1000 comes in formula. give me the formula.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Electromagnetic torque developed by the motor is compared to shaft torque. A less B same C depends on motor design D more

2094


how is the magnetic current test is different in delta-star and delta delta transformer.

2243


details of oil cell size of Breakdown voltage test of tranformer oil details as per Standardswith mushroom electrodes?

1930


sir i applied for hpcl(electrical).i want to know from which subjects most of the technical que will b asked.and pattern of the written test.pls help me

1990


what is difference between bus coupler and auto transfer switch

4262


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2197


how to calculate the size of the HT cable

1932


How to know about the rating(voltage and other) of induction motor if its name plate is missing at the manufacturing site.

3447


what is mean by PIR in circuitbreaker and give me detail of that?

3573


What is the difference between single core 2 wire and single core 3 wire system? Which application we are using this? and for What purpose we are using this?

2384


what's the simultenous maximum demand (SMD)..what the diffrent MD and SMD?

2618


how to calculate the formula of cable size if motor kw is given

2353


how can i determine the gear ratio for a rack and pinion system if an electronic gate operated by an electric motor is to travel a distance of 5meters in 15 seconds.

2086


why ct ,cvt should be stored in a vertical position?

2692


what is capacitor voltage transformer?? how it is different from potential transformer?

2239