Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is input and output of vaiberation transmitter and what is its unit.

Answer Posted / bala

input for vibration prob is -24v but 24v also possible but they use -24v because its NPN transistor as per bently nevada. then out put is -10v or based on settings.

Is This Answer Correct ?    4 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

anybody having Qatar Petroleum questions for instrument Technician offshore ....please send me

6033


Why MUX JB's are using only Temperature Element in Fundation field bus?

2336


Specify ideal accuracy of flow element like orifice plate, Ventury, Annubar. Ultrasonic flow meter etc.

1917


What is difference between differential pressure & delta pressure?

1102


How to calibration coriolis flow meter?

1821


Exothermic reaction./ endothermic reaction

2037


how radio frequency level probes works with its controller ? what is its principle ? pls give me brief explanation?

1891


how to calibrate mass flow meter (Coriolis)? Example calibration range: 0 to 2500 kg/hr line size 3" fluid: Etheline glycol (MEG)

2685


If P will increase then what will happen with PID?

6065


what is function of SCADA , and how is it work, explain with difination

2375


Manipulation of dead wt. tester double piston type.

2059


what is sliding spool valves?

2238


i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....

1470


How to calibrate Toxic gas detector?

1717


What is force balance principle?

1177