if u have to run a 300kw moter then what is ur choice HT or
LT switchgear & explain why?

Answer Posted / sadam hussain gaad

Depends upon application.
if all other motors are operated on HT/LT then 300 KW motor
should be opertaed on HT/LT respectively.

If your generation is HT and you want operate on LT then
you have to install VCB, Transformer, ACB and size of cable
will be more as compared to HT but less insulation will be
required.

If you want to operate 300 KW on HT then no need of
transformer,ACB, only XLPE cable will be used.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why Ac Systems Are Preferred Over Dc Systems?

799


Why PS class CT is always preferred for Differential protection?

1100


List the characteristics of filter?

626


What is float cum boost charging system?

1589


Is there any problem about which the drive (inverter) doesn't show/display the alarm and/or fault but instead of this , it doesn't work ? I want to know that could there be any kind of problem in the drive when the drive doesn't display the alarm and/or fault ?

1520






Dear sir, my knowledge about cable size determination is limited. Though I read examples I could not calculate the Cable size required for electric driven pump 40 KW, 380 Volt, 50 HZ, 50 meter from transformer and it is three phase star delta starting. Please help as there is no one in my surroundings to help.

1295


HAI SENT HPCL APTITUDE QUESTION PAPER, MY EMAIL ID IS angus_eee04@rediffmail.com,angus_eee04@yahoo.com

1716


What is the difference between electronic regulator and ordinary rheostat regulator for fans?

576


PLEASE INFORM ABOUT THE IDEAL TEST RESULTS OF MAGNETIC BALANCE TEST OF TRANSFORMER 33/11 kv DELTA-STAR T/F

1789


What is conventional thermal current (Ith)

3830


Define step response?

652


1 “earthing” for bonding of equipment and circuits to common plant earth electrode potential, 2 “protective earthing (PE)” when this bonding is required for personal safety provisions 3 “grounding” for interference suppressing bonding of screens, sys-tems with ground level 4. low-impedance earthing ? 5.primary earthing system and secondary earthing system what is that? 6.earthing electrode or mesh net earthing electrode ? very confusing , simple but very informative help required ? i will be very very thankful to you guys.

1612


why can the rotor of 3 phase slip ring induction motor not be a 2 phase rotor?

1566


I have a CT meter with ratio 60/5. The meter reading of previous month was 3290.49 and that of current month was 3797.26. How many chargeable units as per normal meter should be my reading.

986


can someone explain that how the speed of the protection system affects the fault level calculation?

1478