Answer Posted / wareagle
simon says
30Kva=30,000va
30,000 VA=440V*68.1818 Amp*1 (Pf)
Hense Ka=0.068 Wrong
Simon if you look at the post, the voltage is 380 volt and
not 440 volts as you posted. Also you incorrectly forgot to
use 1.73 when working with 3 phase voltage.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
hai...... tis is Hemanth. jst now completed electrical engineering... i wanna to apper for ap tranco exam... plzz send me the previous q's paper link......thanx in advance.
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
when we design electrical schemes of 11/.415kv distribution..wen and were should we show the relays??what is the function of it?for example..we place EFR Relay CT between transformer neutral link and transformer earth.Like this what are the other type of relays we should use?why?where?Explain please..Thank you
DC transmission
Why is the frequency not changed during transformation of electrical energy in a transformer?
How to calculate the time setting for star connection in star delta starter? For example 10KW 3PH Induction motor.
PLEASE ANYBODY HAVE ELECTRICAL CIRCUIT DIAGRAM FOR CHMER PULSE CD 60M SPARKING MACHINE.PLEASE MAIL ME SUPRIYAAYYAPPAN@YAHOO.CO.IN.
1.WHAT IS A SMART CAPABLE DB ( DISTRIBUTION BOX) ? 2. HOW TO DECIDE THE TYPE OF DB TO BE USED ( RECESSED/ PLUG TYPE/ SMART ETC ETC? 3. WHAT IS MILLENEUM BUS BAR USED IN DB? 4.DIFFERENTIATE MCCB AND MCB.
What Is Sampling?
hello friends..... any one have papers or any study materials?sail ,hpcl...?
if the motor rated speed is 950rpm. how to change the above rated speed? is it possible?
what happen if the parallel generator phase angle shift by 1 degree in manual mode
A 230V dc shunt wound motor has an armature resistance of 0,15Ω.When operating on no load at 650 rev/min the armature current is 6A . The motor takes a full load current of 85A. Calculate the full load speed if the field flux is (i) maintained constant (ii)reduced by 0,03
What happen if we apply square wave or traiangular waveform voltage to the transformer primary winding instead of sinusoidal wave?
Difference between transition and diffusion capacitance