1. what is 3 point calibration & 5 point calibration?
2. If we use hart communicator to set the LRV & URV of a
smart transmitter, did we calibrate the transmitter? why?
3. Make a complet list if meterials needed to properly
connect a pressure gauge to a steam pipe using 1/2 inch
stainless steel tubing. The gauge connections is 1/2 inch
NPT-M and the steam pipe tap has a 1/2 inch female coupling,
compression fittings are use.
4. What are the tools in loop checking?
5. What would the ISA symbol of a square root extractor look
like?
6. What would you do to completely prepare for the
configuration?
7. What safety measures must you undertake when doing
configuration?
8. what are the two most commonly use programming languages
used when we configure a PLC?
9. What would you do if you accidentally skipped a step in
the configuration procedure?
10. How would you know if the configuration were sucessful?
11. Name at least 3 selections available when we configure
the burnout protection of a controller?
Answer Posted / anand.r biocon limited
1. 3 & 5 point calibration
When calibrating the field instruments or device under test only 3 process reading compared with master instrument for 5 point calibration you should do comparison for 5 process values with master instrument
2. If we use hart communicator to set the LRV & URV of a
smart transmitter, did we calibrate the transmitter? why?
This is not calibration of transmitter we can say this is configuring BASIC parameters to the TX.
3. Make a complet list if meterials needed to properly
connect a pressure gauge to a steam pipe using 1/2 inch
stainless steel tubing. The gauge connections is 1/2 inch
NPT-M and the steam pipe tap has a 1/2 inch female coupling,
compression fittings are use.
By using sypon and 1/2 " nipple you can mount the pressure gauge on steam line if the line is vertical you should have 45 deg angle to the process line to reduce the pressure drop across the instrument.
8.. what are the two most commonly use programming languages
used when we configure a PLC?
Ladder logic
FBD- Functional block diagram
| Is This Answer Correct ? | 14 Yes | 0 No |
Post New Answer View All Answers
what is the diffrence between pressure safety valve & pressure relief valve....pls
How r the calculation of process line mpm.
How hart protocol can be connected with control valves?
sir, i preparing hpcl,ongc,barc,hal exams(instrumentation engg)pls send a placement papers
what is Best Among SINK Or SOURCE Type Design In Digital Signal, Either Iput Or Output? WHY?Can any one..
How can you add value to this Industry if offered the job?
Which type of diaphragm use in costic line, dm water line, natural gas line, oil line?
what is the process for double acting cylinder pneumatic for 32' v/v
Why do you want to work here
Can combine control system for Emergency control system (ESD)and Fire & Gas System ( F & G) is possble to built and offer to client? Can such system is as per Norms in India?
why we are using digital signals for I/O & how to measure this signals is getting or not ?
How to calibrate Magnetic flow Transmitter in Field
sir i m preparing for BARC but i am not getting any papers to prepare for this exam so please send me some sample papers to my i.d for the preparation of barc.
Why we are using DPT(Differential Pressure Transmitter) in separator instead of level trasmitter?
What is motion balance principle?