what do you mean by leading power factor & lagging power
factor
Answer Posted / simon
Pf is of 3 types i.e
1.Leading (Xc>Xl)
2. Lagging(Xc,Xl)
3.Unity (Xc=Xl)
1.In A.C Circuit if cap Reactance's has more current in comparison of inductive reactance's then Voltage will lead.
2.In A.C Circuit if cap Reactance's has less current in comparison of inductive reactance's then Voltage will lag.
3.In A.C Circuit if both r equal then it will b unity.
| Is This Answer Correct ? | 0 Yes | 3 No |
Post New Answer View All Answers
Earth bits close or open. Which is correct
For a stable system, where should the poles of a system be in a root loci plot?
what is EIB lighting control system? what is the advantages of this system?
Where I can get the sample question for post of Junior engineer electrical-II For RRB Bhubaneswar.
Which is the oldest hydropower plant in india?
hi all i like to know vat is power plot in control systems also i want to know abt latest trends in electrical & electronics
DESCRIBE THE CONSTRUCTION ANDOPERATION OF BELT CONVEYORS AND SCR CONVEYORS , DRAW NEAT SKETCHES
when ac current flows thru d coil of a contactr,it energizes,magnetic field attracts d contact of the coil...nw wont dt ac current in d contct induce current back on to d coil thru mutual inductance leading to high currnt in d coil
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
BSNL TTA EXAM QUESTION
How to choose the vector group for the step up and step down transformers??? Tell me the which vector group is suitable for step up and step down transformers and whats the reason to choose and whats the benefits???
how can maintaince the acb contactor moveing and fixing kit
what will be happen if earth point is being used for as a neutral point for raw power , and same will be used for ups earthing
What safety precaution are to be taken for avoiding electric hazards ?
kVA rating of ordinary transformer is increased when connected as an auto transformer because A transformation ratio increased B secondary voltage increased C energy is transferred both inductively and conductively D secondary current increased