A 30KW motor running at 1450 rpm draws 56A, how would you
determine if this is correct or not?
Answer Posted / divakaran a
P=1.732xVxIxP.F
30KW=1.732x415xIx0.8
I=30000/(1.732x415x0.8)
I=52.17 AMPS
sO the current drawing from the motor is 52 amps (Theoriticaly)
in practical the motor may draws more current as based on the load.
Is This Answer Correct ? | 13 Yes | 2 No |
Post New Answer View All Answers
we have an energy meter in a capacitor bank panel, So should we consider it's readings as energy consumption on daily basis. (when capacitor bank doesn't have any energy losses)
What are the parts in a inverter?
What is line resistance of cable & how it can be measured ?
WHAT IS DOL STARTER? HOW IT WORK? GIVE ITS CONTROL AND POWER DIAGRAM .
# 4 hi friends i m from electrical branch and seeking for tech. + apti. both papers of hpcl plz get it available as soon as possible my email id is sumit_lig189@yahoo.co.in
WHAT IS SHORT CIRCUIT STRENGTH OF 100 AMPS MCCB?
Why cables and busbar both needed in LT Panels?
why are distributed windings generally used in alternators?
In ht capacitor ckt we are using LBS Panel it having isolator with fuse, one of HT fuse flash over, so what is reason behind this event.
List the time domain specifications.
the winding of Generator and Motor is star or in delta ? and why
what is stper motor
show the single line diagram of star delta starter with single phase preventer
The specific heats of the gas at constant pressure and constant volume are respectively 1.0 kJ/kg K and 0.72 kJ/kg K; the value of R for the gas is
how can we phase identification in a distribution line,how we recognise that which phase is coming for a house hold connection.help me............