Dear Sir,
This is Thirunavukkarasu am working in Ordain Health Care
AR&D, Am Having one problem While doing method development
my question Metadoxine and Pyridoxine same chemical nature
and structural activity i tried lot of methods but Analyte
eluted same Retantion time i cant separate both peaks.
solubility, pH both are same only only difference melting
point metadoxine 210 C Pyridoxine 102 C please do the help
needful for me
Answer Posted / bpatel1773
Dear ,
I thing you want to isolate both compound , You can try
derivatization method using bezoyl chloride or densyl
chloride . Bezoyl chloride will react with only metadoxine
and it will eluted late on HPLC . This way must work .
Benzoy chloride will react at RT only
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
How they found 1mL of K.F reagent is equivalent to 5mg of water and if we change the composition of K.F reagent, is it can neutralize more amount of water?
how many types of balance calibration test?
What is the principle of Thermal conductivity detector and FID?
In HPLC (Waters) software Empower1,2 &3 what is the updation for each version
Loss of linearity in tkn analysis, possible reasons?
How to fix the sample conc. in Related substances test by HPLC?
How we can identify process related and degradation impurity in single method with short period?
What is third generation HPLC Columns?
Which type of column should i use to check the purity of high molecular weight protein using HPLC reverse phase column chromatography? Hi everyone. I wanna to check the purity of high molecular weight protein (collagen) with MW of ~130 kDa using a HPLC. I know C18
How require to develop GC method? how to select diluent, GAS, column selection and other chromatographic conditions?
in api coa contains only process impurities and in product coa contains degradation impurities?
In Dissolution Test why limit is define Q+5% what is the role of +5%.
in dissolution if one bowl got 70 percent 2nd bowl got 80 percent and 3rd bowl got 90 percent then how proceed?
why we are using hexane in calibration of number of drop per mL