Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Transmitter reading is zero but in DCS showing one Bar what is the reason ?

Answer Posted / atul bharadiya

in field measuring unit is BARG & dcs Unit is BAR A,means
gauge & absolute pressure

Is This Answer Correct ?    2 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

sir, i preparing hpcl,ongc,barc,hal exams(instrumentation engg)pls send a placement papers

2325


flow transmitter formula?

2801


what is the importance of CV in the control valves? how it is calculated?

2433


why we should maintain neutral earth voltage below 1V while calibration? why cant it be 1.2V or 2V

2426


What is difference between radial vibration and axial vibration explain in detail .

1703


-/5A. What is the meaning and limitations of this in energy meter constant. It is a 3 phase LT Energy Meter. If this Energy Meter is connected through a CT of ratio 200/5 Amps, then what is the multiplying constant and how its will be calculated.

2439


How it the difference between force balance system and dispalacement balance system?

2086


Explain how thw analog to digital converter works with the circuit diagram

2663


Why grounding is necessary? Give example with diagram.

2201


can anyone tel the syllabus or previous year question paper for BHAVINI(EIE)2014.

2435


Why MUX JB's are using only Temperature Element in Fundation field bus?

2322


i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....

1457


How many are the types of instrument cables in terms of No. of pair.

2184


What is the meaning of wet leg

1231


what is the responsibility of an instrument commissioning supervisor

3150