Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

I've descovered that when the earth wire in a domestic
electrical installation is not connected back to the board
(ground) a voltage of between 9-24v is is found to be
present in the earth wire.
When connected at the board there is no voltage - is this
normal and why does it happen?

Answer Posted / kj

You will find that no insulation is perfect. There will
always be some leakage. As well there will be induction
into the wire because it is run next to the phase and
neutral. Both of these can account for a voltage in the
earth wire when disconnected.
I would expect a higher reading if the voltage was due to
leakage in the insulation. This could be up to phase
voltage but with no current capacity.
I would think the reading is most likely induction. The
voltage here would increase depanding on the current and
the length that the earth was run with the phase and
neutral.
When it is connected to the earth in the board the voltage
is drained away as in both cases there is only negligible
current capacity.

Is This Answer Correct ?    0 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the best method of grounding in 30 MW generator?

2076


3- What is the target from Zero Impedance, Single Phase Imp., S/C Imp. and magnetic balance tests?

1929


Disadventage of cable-gland earthing if any ?

2308


what is the maximum temperature rating of a thhn insulated conductor?

1902


Why Ac Systems Are Preferred Over Dc Systems?

1354


what is meant by directional earth fault and non directional earth fault? describe both.

1945


What is an iron loss or core loss pi?

1176


describe the A.C. Generator Testing procedure

2225


What is the meaning of 40X8X2 busbar dimensions for carring load of 400 Amps

2041


What is the Difference between Ac Drives and Dc Drives? According to application, speed, Torque, cost, Reliability, Construction, Motor etc... Thankyou !!!

2247


what is meant by brushed alternator & its working principle ?

1974


how can you calculate fault level ?

2449


what is reactive power?, why its measured in VA ? is it transient behavior of system?

2350


What is meant by analogous system?

1371


What are the material used for resistor?

1153