Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how can we change the rotating direction of single phase AC
induction motors?

Answer Posted / sona vijay shah

For changing the direction of rotation of a single phase
induction motor u reverse either starting winding
connection or running winding (but do not change both
winding connection otherwise it will rotate in the same
direction). For this you can simple reverse the connection
of capacitor.

For three phase motor interchange the connection of any two
phase.

Is This Answer Correct ?    13 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

state types of reflectors in illumination engg. ???????

1995


how can see the ac indoor or out door ac which Tr

2064


why voltage form factor of PT are increase , when it is ecpected heigher spikes in system. how it is calculated.

2206


Please brief what is sinewave

2199


what do u understand about FACTS? how they are useful?

2049


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2198


how can i determine the gear ratio for a rack and pinion system if an electronic gate operated by an electric motor is to travel a distance of 5meters in 15 seconds.

2088


. What is Electrical Life & Mechanical Life of Circuit Breaker? 2. What is Electrial Life & Mechanical Life of Magnetic Contactor? 3. What is RCD, RCCB & RCBO? 4. What is the Between defferance of RCD, RCCB & RCBO?

3403


How much load can be taken for chiller from 1500 kva transformer

1325


what is cogging and crawling

2602


use of PIR in ehv breaker

2210


How to see the inductance in a transmission lines

2184


What is the main cause of magnetism?

2132


RATING OF LIGHTENING ARRESTER FOR 11 KV LINE IS 9 KV is ok ,but haw to calculate the KA rating?

2138


how to test the electrical panel.ht lt mcc pcc.