Dear sir,We have a 7.5hp motor,it was running smoothly and
suddenly one winding is carring more current then
others(r=6.5,y=6.3,b=10)..whts wrong with tis...?
Answer Posted / kingniki
We can check by continunity on winding from multimeter and that time it shows that motor becomes unbalanced
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Can any one give an explanation about rating factors of cable? if we are laying the cable on the air with an temp 15 degree then rating factors will be 1.15 and if we are laying the cable on the air an temp 60 degree then rating factor will be 0.76 please describe it and what is the difference between rating factor and derating factor?
CAN ANYBODY PLEASE TELL ME HOW TO DESIGN A SERIES REACTOR FOR LIMITING SHORT CIRCUIT FAULT CURRENT??
what is the difference between general inverter and solor inverter clerly explain plz
2. What are the parameters of EHT sub-station?
How to protect sensitive loads such as Dosing pumps inside a factory from voltage surge/voltage fluctuation.
In a Impedance Based Distance Relay (Quad Characteristics) - Could there be two different Line Angle(RCA) for Ph-Ph & Ph-Gnd? If So Kindly Let me Know.. Where, What are the advantages of the same?
In constant power region of 3-phase IM torque-speed characteristics, if frequency increases flux A does not alter B decreases C increases D none of above
how can i use REF and diffrencial relay both in 1 CT core for transformer protection?
What is the tube exial fan?
Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.
Dear All, I am new in construction company , my boss ask a question at time of interview , If we have 60MW generation and Single Power Transformer step-up we have. if CMR 50/60MVA , ONAN, ONAF respectively , is it sufficient or not ? for that much power to transfer,
Do u know any one? how to find out in motor rated amps? formula?
For the requirement of a furnace of temperature range up to 1200 oC using silicon carbide rods, What is the required rate of transformer needed (please do it with all details)?
how to erect roof control panel?
What is the difference between cylindrical-type and sandwich-type winding?